MODELSNF-ZXYS010

Advanced Blood Pressure Measurement Arm Model

Main functions: 1、The model is the shape of the right arm of an adult, with obvious anatomical landmarks and real texture. The real blood pressure monitor can be used for noninvasive blood pressure measurement. 2、the radial artery and brachial artery can be touched to measure the pulse. 3、The values of systolic blood pressure, diastolic blood pressure and pulse frequency can be adjusted according to the teaching situation.Customized systolic blood pressure (70-250 mmHg)and diastolic blood pressure (40-140 mmHg) are supported, covering clinical scenarios such as normal value, hypertension, and hypotension. Blood pressure Settings can be accurate to 1mmHg,and pulse rates can range from 0 to 180 beats/min. 4、with KorotkoffGap sound, support real stethoscope use. Five stages of sound changes are clearly presented. The volume is adjustable.

CATEGORY
Nursing Care
SUB-CATEGORY
Advanced Blood Pressure Measurement Arm Model
Manufacturer directExport supportConfiguration support
Ask on WhatsApp

OVERVIEW

Main functions: 1、The model is the shape of the right arm of an adult, with obvious anatomical landmarks and real texture. The real blood pressure monitor can be used for noninvasive blood pressure measurement. 2、the radial artery and brachial artery can be touched to measure the pulse. 3、The values of systolic blood pressure, diastolic blood pressure and pulse frequency can be adjusted according to the teaching situation.Customized systolic blood pressure (70-250 mmHg)and diastolic blood pressure (40-140 mmHg) are supported, covering clinical scenarios such as normal value, hypertension, and hypotension. Blood pressure Settings can be accurate to 1mmHg,and pulse rates can range from 0 to 180 beats/min. 4、with KorotkoffGap sound, support real stethoscope use. Five stages of sound changes are clearly presented. The volume is adjustable.

FEATURES & SPECIFICATIONS

Detailed specification text is not published for this model yet — the overview above is the complete published record.

TECHNICAL PARAMETERS

Specifications:

  1. This model simulates an adult right arm with distinct anatomical landmarks and realistic material texture. A real sphygmomanometer can be used for non-invasive blood pressure measurement.

  2. The pulses of the radial artery and brachial artery are palpable for pulse assessment practice.

  3. The values of systolic pressure, diastolic pressure and pulse rate can be adjusted according to teaching requirements. Customizable systolic pressure ranges from 70 to 250 mmHg and diastolic pressure from 40 to 140 mmHg, covering normal, hypertensive and hypotensive clinical scenarios. The blood pressure setting can be accurate to 1 mmHg, and the pulse rate ranges from 0 to 180 beats per minute.

  4. It is equipped with Korotkoff sounds for use with a real stethoscope. The sound changes of five phases can be clearly presented, and the volume is adjustable.

MODEL-SPECIFIC INQUIRY

Need a quotation or configuration advice?

Send this model directly to our sales team. We will reply with configuration options, lead time, and export support.
Ask on WhatsApp