- Procedure
- Preoperative Preparation
① Patient Preparation
- Explain the purpose, procedure, and potential risks of lumbar puncture to the patient,
- Examine the patient's fundi for papilledema and review the patient's cranial CT and MRI images
- Obtain Written Informed Consent
Note: Communicate with the patient before the procedure and confirm informed consent.
② Equipment preparation
- Sterile lumbar puncture kit containing a kidney dish, lumbar puncture needle, fenestrated drape, hemostatic forceps, towel clamp, small antiseptic cup, gauze, and specimen container.
- Sterile gloves.
- Procedure tray.
- 5ml syringe.
- Disposable Manometer Tube
- 2% lidocaine.
- Povidone-iodine, gauze, and adhesive tape.
- Procedure
① Position: Place the patient in the lateral decubitus position near the edge of the bed, with the head flexed toward the chest and both knees drawn tightly toward the abdomen. This position maximizes posterior flexion of the spine to widen the intervertebral spaces.
For patients with obesity, arthritis, or scoliosis, lumbar puncture may also be performed in the seated position.
② Determine the puncture site: The puncture site is generally where the line connecting the highest points of both iliac crests intersects the posterior midline (corresponding to the L3-L4 interspace). The interspace immediately above or below may also be used.
Note:The puncture site is generally the intersection of the posterior midline and the line connecting the highest points of the bilateral iliac crests.
③ Open the lumbar puncture kit, don sterile gloves, disinfect the puncture area with povidone-iodine over several interspaces, and apply a fenestrated drape.
④Inject lidocaine subcutaneously at the L3- L4 interspace to raise a wheal;then anesthetize the deeper structures.
Note:Procaine may also be used for anesthesia; a skin test is required before administering procaine.
⑤Inspect the lumbar puncture needle for defects. Stabilize the skin at the puncture site with the left hand, hold the lumbar puncture needle in the right hand, and insert it perpendicular to the back through the skin wheal
Advance slowly, angling the hub of the lumbar puncture needle toward the patient's feet by 30°-45°
⑥Advance the needle slowly into the subarachnoid space. A sudden loss of resistance is felt as the needle passes through the ligaments and dura mater. An inexperienced operator may repeatedly remove the stylet to check for cerebrospinal fluid flow. Remember to insert the stylet before each advancement; when withdrawing the needle, it is not necessary to insert the stylet. During puncture, the bevel of the lumbar puncture needle should be parallel to the patient's longitudinal axis to avoid damaging dural fibers and thereby reduce post-lumbar-puncture headache.
Note:During puncture, the bevel of the lumbar puncture needle should be parallel to the patient's longitudinal axis to avoid damaging dural fibers and reduce post-lumbar-puncture headache.
⑦If no cerebrospinal fluid flows, gently rotate the lumbar puncture needle. If cerebrospinal fluid still does not flow, air may be injected,but do not inject saline or distilled water.
⑧ Once cerebrospinal fluid begins to flow, connect the manometer to measure the pressure. Normal opening pressure is 70-180 mmH2O (lateral decubitus position). Elevated pressure may be seen with patient anxiety, subarachnoid hemorrhage, infection, or a space-occupying lesion. Low pressure may indicate obstruction of cerebrospinal fluid circulation or that the lumbar puncture needle tip is only partially within the subarachnoid space.
Note:The normal opening cerebrospinal fluid pressure in the lateral decubitus position is 70-180 mmH2O.
⑨ Collect 2- 5ml of cerebrospinal fluid for laboratory testing in the following order:
Use the first tube for bacteriological testing:Gram staining, fungal staining, and fungal culture;
Use the second tube to test glucose and protein. If multiple sclerosis is suspected, test for oligoclonal bands and myelin basic protein.
Use the third tube for cell count and differential;
Use the fourth tube for specific tests based on the patient's condition: test for VDRL if neurosyphilis is suspected; perform PCR testing if tuberculous meningitis or herpes simplex encephalitis is suspected; perform an India ink stain if cryptococcal infection is suspected.
⑩Withdraw the lumbar puncture needle and cover the puncture site with dry gauze.
Note:Instruct the patient to lie flat without a pillow for 4-6 hours and drink plenty of water to prevent post-lumbar-puncture headache.
- Precautions
- Contraindications must be strictly observed. Any patient with suspected elevated intracranial pressure must undergo funduscopic examination. Puncture is contraindicated in the presence of marked papilledema or signs of impending brain herniation.
- Puncture is contraindicated in patients who are in shock, severely debilitated, or moribund; have inflammation of the skin at the puncture site; have a space-occupying lesion in the posterior cranial fossa; or exhibit brainstem signs.
- After the needle enters the subcutaneous tissue, advance it slowly. Excessive force may injure the cauda equina or blood vessels, causing lower-extremity pain or contaminating the cerebrospinal fluid with blood and affecting interpretation of the results.
- If the patient develops abnormalities in breathing, pulse, complexion, or other symptoms during the puncture, stop the procedure immediately and provide appropriate treatment.
- For intrathecal drug administration, first withdraw an equal volume of cerebrospinal fluid, then inject the medication.
- For pneumoencephalography, first slowly drain 10 mL of cerebrospinal fluid, then inject 10 mL of filtered air. Repeat this process until the required volume has been reached, and then obtain the radiographs.
- Cerebrospinal fluid should not be drained too rapidly; the usual rate is 10-15 drops/min. In patients with normal intracranial pressure, no more than 5ml of cerebrospinal fluid should be drained at one time to prevent brain herniation from occurring.
- Practical Demonstration Video